This event is fired when a sheet has been scanned and reaches the print head. Relevant information such as the printer string, stacker selection, sheet number and partial data record for the document being scanned are packaged into an object of type SheetOutput and passed as a parameter to the event handler.
The event handler may have code to do one or more of the following:
The ScanningManager Stop method may be called from within this event handler.
If the scanning session is asynchronous, scanning will resume once control reaches the end of the handler.
If the scanning session is synchronous, scanning will pause after the handler until a BlockForScannerEvent method is issued.
void OnSheetAtPrintHead([in] ISheetOutput* sheetO);
ISheetOutput* sheet0 |
Pointer to the SheetOutput object for the sheet just scanned. |
How to Implement Event Driven Scanning
ScanningManager.ModifyPrintString method
ScanningManager.ModifyStackerSelection method
See Help on Help for additional information on using this help file. See Scantron Technical Support for additional information on technical support and training options. See the ScanTools Suite System Requirements for further details on hardware and software requirements. ScanTools is a suite of products; the specific information you want may appear in the help for a different module. If you don't find what you're looking for here, try one of the following:
|
Scantron Corporation
Customer Service (forms, products, and services): 1-800-SCANTRON (722-6876) Technical Support: 1-800-445-3141 |
|
Copyright © 1998-2012 Scantron Corporation. All rights reserved. Use permitted only under license. www.scantron.com. No part of the Help or user guides may be reproduced in any form, or by any means, without express permission from Scantron Corporation. LINKS TO THIRD PARTY SITES This help system may contain links to third party websites ("Linked Sites"). The Linked Sites are not under the control of Scantron and Scantron is not responsible for the content of any Linked Site, including without limitation any link contained in a Linked Site or any changes or modifications to a Linked Site. Scantron is not responsible for web casting or any other form of transmission received from any Linked Site. Scantron provides Users with the ability to link the Assessment System to the Linked Sites as a convenience to you, and the inclusion of any link does not imply endorsement by Scantron of the Linked Site or any association with its operators. |